Data Source: oci_monitoring_alarm_history_collection
This data source provides details about a specific Alarm History Collection resource in Oracle Cloud Infrastructure Monitoring service.
Get the history of the specified alarm. For more information, see Getting History of an Alarm. For important limits information, see Limits on Monitoring.
This call is subject to a Monitoring limit that applies to the total number of requests across all alarm operations. Monitoring might throttle this call to reject an otherwise valid request when the total rate of alarm operations exceeds 10 requests, or transactions, per second (TPS) for a given tenancy.
Example Usage
data "oci_monitoring_alarm_history_collection" "test_alarm_history_collection" {
#Required
alarm_id = oci_monitoring_alarm.test_alarm.id
#Optional
alarm_historytype = var.alarm_history_collection_alarm_historytype
timestamp_greater_than_or_equal_to = var.alarm_history_collection_timestamp_greater_than_or_equal_to
timestamp_less_than = var.alarm_history_collection_timestamp_less_than
}
Argument Reference
The following arguments are supported:
alarm_historytype
- (Optional) The type of history entries to retrieve. State history (STATE_HISTORY), state transition history (STATE_TRANSITION_HISTORY), rule history (RULE_HISTORY) or rule transition history (RULE_TRANSITION_HISTORY). If not specified, entries of all types are retrieved. Example:STATE_HISTORY
alarm_id
- (Required) The OCID of an alarm.timestamp_greater_than_or_equal_to
- (Optional) A filter to return only alarm history entries with timestamps occurring on or after the specified date and time. Format defined by RFC3339. Example:2023-01-01T01:00:00.789Z
timestamp_less_than
- (Optional) A filter to return only alarm history entries with timestamps occurring before the specified date and time. Format defined by RFC3339. Example:2023-01-02T01:00:00.789Z
Attributes Reference
The following attributes are exported:
alarm_id
- The OCID of the alarm to retrieve history for.entries
- The set of history entries retrieved for the alarm.alarm_summary
- Customizable alarm summary (alarmSummary
alarm message parameter). Optionally include dynamic variables. The alarm summary appears within the body of the alarm message and in responses to ListAlarmStatus GetAlarmHistory and RetrieveDimensionStates.summary
- Description for this alarm history entry.Example 1 - alarm state history entry:
The alarm state is FIRING
Example 2 - alarm state transition history entry:
State transitioned from OK to Firing
timestamp
- Timestamp for this alarm history entry. Format defined by RFC3339. Example:2023-02-01T01:02:29.600Z
timestamp_triggered
- Timestamp for the transition of the alarm state. For example, the time when the alarm transitioned from OK to Firing. Available for state transition entries only. Note: A three-minute lag for this value accounts for any late-arriving metrics. Example:2023-02-01T0:59:00.789Z
is_enabled