Roving Edge Infrastructure Device Specifications
Describes the hardware and port specifications for Roving Edge Infrastructure devices.
Hardware
The following table lists the hardware specifications of the Roving Edge Infrastructure devices. Specifications are for the maximum configuration.
Roving Edge Device |
Roving Edge Device – Compute Shape |
Roving Edge Device – GPU Shape |
Roving Edge Device – Storage Shape |
Roving Edge Ultra |
|
---|---|---|---|---|---|
Shape Name |
RED.GPU.1.RX1.40 |
RED.2.56 | RED.2.56.GPU | RED.2.56.STG | ULTRA.USB.1.RX2.12 |
Object, Block, and Filesystem Storage |
61 TB raw |
4 x 15.38 TB SSDs providing:
|
4 x 15.38 TB SSDs providing:
|
8 x 15.38 SSDs providing:
|
7.68 TB raw Removable NVMe-based Ignition Key (512 GB) for added security which contains the Roving Edge Infrastructure device operating system and the keys to decrypt the data drive. |
Available OCPU |
32 |
48 |
48 |
48 |
8 |
Usable Memory available for VMs |
390 GB DDR4-2933 |
384 GB |
384 GB |
384 GB |
64 GB DDR4-2400 |
GPU |
NVIDIA(R) Tesla(R) T4 GPU 2650 cudas cores, 320 sensor cores |
N/A |
3x NVIDIA Corporation AD104GL [L4] |
N/A |
No integrated GPU. Supports up to 2 Intel Movidius VPUs via USB |
CPU |
2 x Intel(R) Xeon(R) CPUs Gold 6230T @ 2.1Ghz, 40 total cores |
1x Intel 8480+ Sapphire Rapids, 56C, 350W |
1x Intel 8480+ Sapphire Rapids, 56C, 350W |
1x Intel 8480+ Sapphire Rapids, 56C, 350W |
Intel(R) Xeon(R) CPU D-1559 @ 1.50GHz, 12 total cores |
Networking |
2x10GbE (1 active) |
3x Quad port Intel Corporation Ethernet Controller X710 for 10GBASE-T |
1x Quad port Intel Corporation Ethernet Controller X710 for 10GBASE-T |
1x Quad port Intel Corporation Ethernet Controller X710 for 10GBASE-T |
2x1GbE (1 active) |
Security |
TPM, Trenchboot SecureBoot, physical tamper evidence |
TPM, Trenchboot SecureBoot, physical tamper evidence, chassis intrusion detection |
TPM, Trenchboot SecureBoot, physical tamper evidence, chassis intrusion detection |
TPM, Trenchboot SecureBoot, physical tamper evidence, chassis intrusion detection |
TPM, Trenchboot SecureBoot, physical tamper evidence Removable NVMe-based Ignition Key (512 GB) for added security which contains the Roving Edge Infrastructure device operating system and the keys to decrypt the data drive. |
Dimensions |
System: 20" L x 17" W x 3.5" H Rugged Case: 38" L x 23.6" W x 11.8" H |
System: 2U – 18.11" L x 16.93 W x 3.46 H Rugged Case: 3U – 35.5" L x 23.8" W x 11.4" H |
System: 2U – 18.11" L x 16.93 W x 3.46 H Rugged Case: 3U – 35.5" L x 23.8" W x 11.4" H |
System: 2U – 18.11" L x 16.93 W x 3.46 H Rugged Case: 3U – 35.5" L x 23.8" W x 11.4" H |
7.4" L x 6.3" W x 2" H without battery 7.4" L x 7.95" W x 2" H with battery pack |
Weight |
33.6 lbs (15.24 Kg) without rugged case 82.6 lbs (37.47 Kg) with rugged case combined weight |
35 lbs (15.9 Kg) without rugged case 91.1 lbs (41.32 Kg) with rugged case combined weight |
35 lbs (15.9 Kg) without rugged case 91.1 lbs (41.32 Kg) with rugged case combined weight |
35 lbs (15.9 Kg) without rugged case 91.1 lbs (41.32 Kg) with rugged case combined weight |
3.75 lbs (1.7 Kg) without battery 4.80 lbs (2.18 kg) with battery pack |
Power Output |
850 W |
1100 W |
1100 W |
1100 W |
55 W |
Input Voltage |
100 - 240VAC |
100 - 240VAC |
100 - 240VAC |
100 - 240VAC |
9 - 36VDC |
Battery Options | N/A |
N/A |
N/A |
N/A |
Voyager1+ (120 W power output with 65 Wh battery backup power) |
80 PLUS Standard |
80 PLUS Platinum |
80 PLUS Titanium |
80 PLUS Titanium |
80 PLUS Titanium |
|
Connector Type |
C14 |
C14 |
C14 |
C14 |
|
Compliance and Certs |
FIPS 140-2 Level 2 MIL-STD-810G MIL-STD-461G MIL-STD-1472H MIL-STD-1474E |
FIPS 140-2 level 2 (TPM) MIL-STD-810H MIL-STD-461G |
FIPS 140-2 level 2 (TPM) MIL-STD-810H MIL-STD-461G |
FIPS 140-2 level 2 (TPM) MIL-STD-810H MIL-STD-461G |
FIPS 140-2 Level 2 MIL-STD-810G/H MIL-STD-461F |
Operating Temp Range |
0 C to 43 C (-5 C to 65 C storage) |
0°C to +50°C |
0°C to +50°C |
0°C to +50°C |
-20 C to 50 C (-40 C to 85 C storage) |
Noise Level |
68.6 - 73.7 dB (at 25 C ambient) |
56.2 dbA (at 25C ambient) |
56.2 dbA (at 25C ambient) |
56.2 dbA (at 25C ambient) |
< 60 dB |
Safety and Compliance Resources
For safety and compliance information, refer to the following documents.
Oracle Engineered System Safety and Compliance Guide
Oracle Engineered System Safety and Compliance Guide (Nordic)
Self-Encryption
Flash storage devices used in Roving Edge Device and Roving Edge Ultra are instant secure erase (ISE) drives. ISE drives behave like full disk encryption (FDE) drives in that the data is encrypted with a hardware key when written to disk, and then decrypted when the data is read from the disk. When the Crypto erase command is sent to the drive, the encryption/decryption key is overwritten, preventing the stored data from being decrypted.
The TPM cryptographic modules used in Roving Edge Devices and Roving Edge Ultra devices are FIPS 140-2 certified.
Tamper-Evident Seals
Oracle applies, maintains, and tracks serialized tamper-evident seals on Roving Edge Device and Roving Edge Ultra. A broken, missing, or damaged label provides a visual indication of a potential hardware breach. Tamper-evident seals aren't FIPS 140-2 certified.
Ultra Battery Options
The following battery options are available for use with Roving Edge Ultra devices:
-
Modular stackable form-factor integrated 75Wh module:
-
Directly attaches to the chassis.
-
Provides up to 1 hour of operation per battery at its maximum CPU load.
-
Has a 60W output.
-
Service Ports
Each Roving Edge Infrastructure device supports a single IP and exposes its services through the following unique ports:
Service |
Port |
---|---|
Identity |
12050 |
Authorization |
12060 |
Object Storage Gateway |
8019 |
Virtual Cloud Network (VCN) |
18336 |
Compute |
19060 |
Data Sync |
21060, 21061 |
Monitoring |
22060 |
System Upgrade |
23060 |
Block Storage |
5012 |
Roving Edge Device Console |
8015 |
Etcd3 |
18000 |
Running CLIs on Device-Hosted Compute Instances
Configure your Roving Edge Infrastructure device to run the command line interface (CLI) on its compute instances.
Follow these guidelines for running CLIs on compute instances hosted by Roving Edge Infrastructure devices.
The instructions in this topic are for Oracle Linux host computers.
-
Have the VM go through the following local IP:
169.254.169.254
-
Have the VM refer to the Roving Edge Infrastructure device as
otec-console-local
. -
Employ the following IP Tables rules:
{ for i in 19060 8019 12050 21060 22060 23060 22060 12060;do iptables -I BareMetalInstanceServices -d 169.254.169.254/32 -p tcp -m tcp --dport $i -m comment --comment "Rover service access port" -j ACCEPT;done }
See Service Ports for a list of available ports.